LOGIC

5-6

Logic 101: The logic for various apparatus

Overview (Logic 101)

This logic is for safety protective measures applicable to production machines and robots. Safety
outputs perform as dual channel outputs.
This logic enables the connection of 2 dual channel direct opening inputs and 4 dual channel
dependent inputs.

System runs

Safety input 1

Safety input 2

Safety input 4

Safety input 3

Safety input 5

Safety input 6

Safety output 1
or
Safety output 2

Emergency
stop switch

Safety switch

Logic 101

Safety
output 1

Safety
output 2

Operation example (Logic 101)

Safety input 1

Safety input 2

Safety input 4

Safety input 6

Safety input 3

Safety input 5

Safety output 1
or
Safety output 2

Open!

Press!

System stops