Logic, Example: auto mode – IDEC FS1A Controller User Manual

Page 293

Advertising
background image

LOGIC

5-245

Chapter 5

Example: Auto mode

Safety input 1: X0
(Mode select input :
Teach mode

)

Safety input 2:
X2, X3

Monitor output for
safety input 2: Y5

Monitor output for
safety input 1: Y4

Start input 1: X16
(Manual)

Safety input 1: X1
(Mode select input:
Auto mode)

State monitor output 3:
Y16

Safety output 1: Y0

Start input 2: X17
(Control)

Monitor output for
Safety output 1: Y12

Safety output 2-1:
Y1

Monitor output for
Safety output 2-1: Y13

Safety output 2-2:
Y2

Monitor output for
Safety output 3: Y20

Monitor output for
safety input 5: Y10

Safety input 5:
X10, X11

Monitor output for
Safety output 2-2: Y17

Safety output 3: Y3

Monitor output for
safety input 3: Y6

Max. 3s

note 3)

Safety input 3: X4,
X5

OFF delay time

0.1s to 5s

Max. 0.1s

OFF delay time

Safety

output

2, 3

ON

Switch to

Teach

mode

Safety

output

2, 3

ON

Safety

output

2, 3

ON

(Safety input 4 is ON in this chart.)

Note 3) When Safety input 1 (mode select input) is switched to another mode within 3s, Safety output 2 is kept ON.

Advertising