This section describes the functions of each logic circuit. The logic functions are separated into
input, logic operation, and output functions in Table 5-1. Select the appropriate logic after
understanding its functionality.

Table 5-1 List of logic functions

Type

Function

Symbol

Description

Reference page

Dual channel direct
opening input

Dual Channel

Direct Opening

This function is for connecting
safety devices with dual channel
direct opening action
mechanisms, such as
emergency stop switches or
interlock switches.

5-311

Dual channel
dependent input

Dual Channel

D

epende nt

This function is for connecting
safety devices with dual channel
dependent action mechanisms,
such as enabling switches.

5-313

Dual channel
NO/NC input

Dual

Channel

NO /NC

This function is for connecting a
safety device with a dual channel
NO/NC mechanism, such as a
non-contact interlock switch.

5-315

Dual channel safety
input

Dual Channel Safety

This function is for connecting
safety devices with dual channel
solid state outputs (PNP output),
such as safety light curtains,
safety laser scanners, or safety
devices with dual channel
contacts, such as emergency
stop switches.

5-317

Mode select input

Mode Select

This function is for connecting
devices with a mode selector
function, such as a mode
selector switch.

5-319

Mode select input II

Mode Select

This function is for connecting
devices with a mode selector
function, such as mode selector
switch. In case of switching if the
input is performed within 3s, the
function output is kept at the
previous state.

5-321

Muting input

Muting input

This function is for connecting a
sensor or any other input device
to perform muting.

5-323

Monitor input

Single Channel

Monitor

This function is for connecting a
switch or sensor for use as a
start input.

5-325

Input function

External device
monitor input

External Device

Monitor

EDM

This function is for monitoring
external devices controlled by
the SafetyOne. External devices
are diagnosed for errors by
connecting a NC contact, such
as a contactor or safety relay.

5-326