Turning on the power, Using the protective cover – IDEC FS1A Controller User Manual

Page 41

Advertising
background image

BASIC OPERATIONS

4-3

Chapter 4

Turning on the power

After the SafetyOne is turned on, it transitions to the Initial state and checks internal circuits.
SafetyOne changes to the appropriate state (in approximately 6s) according to the result of the
internal circuit check. During the Initial state, the LEDs blink to check operation.

Logic switch and timer switch are set Logic: “101” and Timer: “1 (0s)” at the factory. When
initially powering up the SafetyOne, thoroughly confirm the configuration and the operation.

Using the protective cover

●Opening and closing the protective cover
Place your finger at the bottom right of the
protective cover, and open the cover to a position
that enables you to view the configuration options.
The protective cover can be set at two opened
positions (60° or 120°). Be careful not to open the
cover beyond 120°, as this causes the cover to
separate from the body.

Locking the protective cover
After configuration of SafetyOne and confirming,
close the protective cover. To protect the
configuration, it is recommended that the
protective cover be locked.
Use the attached marking tie or
commercially-available wire or a similar
equipment to lock the protective cover. In case of
using commercially-available wire, use wire that
perspnnel, other than safety responsible persons
operating the SafetyOne, are not able to modify.
(ex. Φ1.0 or more metal wire)

Refer to Dimensions in “Chapter 2 PRODUCT
SPECIFICATIONS” for Detail of locking hole.

The protective cover and marking tie do not
ensure mechanical strength against strong force.
The protective cover and marking tie can be
broken with the strong force.

Advertising