background image

LOGIC

5-169

Chapter 5

Example: Auto mode

Safety output 2: Y2,
Y3

Safety input 1: X0
(Mode select input:
Teach mode)

Safety input 4:
X6

Monitor output for
safety input 4: Y7

Monitor output for
safety input 1: Y4

Monitor output for
safety input 5: Y10

Safety input 1: X1
(Mode select input:
Auto mode)

Monitor output for
Safety output 1: Y12

Solenoid output 2: Y20

State monitor output 3:
Y16

Safety input 5:
X10, X11

Start input 2: X17
(Control)

Safety input 4:
X7

Safety output 1:
Y0, Y1

Monitor output for
Safety output 2: Y13

Solenoid output 1: Y17

Max. 0.1s

Monitor output for
safety input 6: Y11

Safety input 6: X12,
X13

Safety
output

ON

Safety input 2: X2,
X3

Monitor output for
safety input 2: Y5

OFF delay time

Start input 1: X16
(Manual)

0.1s to 5s

OFF delay time

Safety

output

ON

Safety
output

ON

Switch to

Teach

mode

OFF delay time

Safety

output

ON

Max. 0.1s

Min. 0.1s

(Safety input 3 is ON in this chart.)