Timing chart (logic 12b) – IDEC FS1A Controller User Manual

Page 151

Advertising
background image

LOGIC

5-103

Chapter 5

Timing chart (Logic 12b)

Example: Manual start input (X16) is used.

Safety input 1: X0

Start input 1: X16
(Manual)

Monitor output for
safety input 1: Y4

State monitor output 3:
Y16

Solenoid output 1:
Y17

OFF delay time

Safety input 1: X1

Max. 6s

Initialization

note 1)

note 1)

Safety input 2:
X2, X3

Safety output 1:
Y0, Y1

Monitor output for
Safety output 1: Y12

Safety output 2: Y2,
Y3

Monitor output for
Safety output 2: Y13

Solenoid output 2:
Y20

Monitor output for
safety input 2: Y5

Min. 0.1s

Max. 0.1s

Power

ON

Safety output

ON

Safety output

ON

OFF delay time

Safety output

ON

(Either safety input 3 or 4 is ON, and both safety input 5 and 6 are ON in this chart.)


note 1) Input monitor error detection time is 0.5s.

About safety inputs that are not described in this chart, input monitor error detection time is as follows.

The time of dual channel direct opening input (X4, X5 and X10 to X13) is 0.5s.

The time of dual channel independent input (X2, X3, X6 and X7) is infinity.

Refer to the following “Logic functions” for more details.