LOGIC

5-197

Chapter 5

Example: Auto mode

Max. 3s

Monitor output for
Safety output 1: Y12

State monitor output 3:
Y16

Safety input 2: X2
(Mode select input:
Teach mode)

Monitor output for
safety input 2: Y5

Monitor output for safety
input 5: Y10

Safety input 2: X3
(Mode select input:
Auto mode)

Start input 2: X17
(Control)

Safety output 1:
Y0, Y1

Safety output 2:
Y2, Y3

Monitor output for
Safety output 2: Y13

Monitor output for
Teach 1: Y17

Safety input 5: X10,
X11

Monitor output for
safety input 6: Y11

Safety input 6:
X12, X13

Monitor output for
Teach 2: Y20

Max. 0.1s

0.1s to 5s

Safety input 1: X0
(Mode select input:
Teach 1)

Monitor output for
safety input 1: Y4

Safety input 1: X1
(Mode select input:
Teach 2)

Monitor output for
safety input 3: Y6

Safety input 3:
X4, X5

Safety input 4:
X6, X7

Monitor output for
safety input 4: Y7

Start input 1: X16
(Manual)

note 1)

OFF delay time

OFF delay time

Safety

output

ON

Switch to

Teach 2

Safety
output

ON

Note 1) When “Safety input 2 (mode select input)” is switched to another mode within 3s, all of “Safety output” are

kept ON.