background image

LOGIC

5-167

Chapter 5

When using the start switch S7

Manual start

When not using the start switch S7

Auto start

When connecting multiple emergency stop switches
in series

NOTE: Safety performance depends on
the system configuration.

When not using some safety inputs
・If there are unused safety inputs in S3 and S6,
connect the unused recieve terminals to the corresponded
drive terminals. (Refer to (1))
・If use only one of S4 and S5, open between the unused
recieve terminals and drive terminals. (Refer to (2))

If unuse both of S4 and S5, connect the recieve rminals

to DC power supply 24V DC. (Refer to (3))

X16
X17

24V DC

S8

X16
X17

24V DC

S7

S8

X12

T12

X13

T13

X4

T4

X5

T5

24V DC

X

p

T

p

X

p+1

T

p+1

X

n

X

n+1

T

n

T

n+1

X

m+1

T

m

T

m+1

X

m

(2)

(1)

(3)