LOGIC

5-274

Functions (Logic 106)


●Safety inputs: X0 to X11
Safety inputs are used to diagnose the status of connected safety devices, such as emergency
stop switches, and interlock switches.

Intended inputs
(Terminal names)

Function

Function name

Dual channel safety input

Symbol

Dual Channel Safety

Description of operation

This function diagnoses the status of
connected safety devices. This
function diagnoses the time interval of
status transition between each input of
duplicated inputs (0.1s). The function
does not use drive terminals (T0 to
T11).

Safety input 1
(X0, X1)
Safety input 2
(X2, X3)
Safety input 3
(X4, X5)
Safety input 4
(X6, X7)
Safety input 5
(X10, X11)

Detail information

Logic functions (5-317)

Warning

For connected control devices, refer to “SAFETY PRECAUTIONS”.

Note. If safety inputs are not used, connect the receive terminals to a 24V DC power supply (V+). If

they are not connected, the SafetyOne does not turn ON the safety outputs.