AT-S63 Management Software Web Browser Interface User’s Guide
Section I: Basic Operations
65
4. Click the Enable SNMP Access checkbox to enable or disable SNMP
management. A check in the box indicates that the feature is enabled,
meaning that the switch can be managed from an SNMP management
station. No check indicates that the feature is disabled. The default is
disabled.
5. If you want the switch to send authentication failure traps, click the
Enable Authentication Failure Traps checkbox. A check in the box
indicates that the switch sends the trap.
6. Click Apply.
A change to SNMP access is immediately activated on the switch.
The community strings that already exist on the switch are displayed in
a table.
7. From the Configuration menu, select the Save Config option to
permanently save your changes. (This option is not displayed if there
are no changes to save.)