4-28

Axxius 800 - Release 2.2

Configuration

Setup of DS0 Management Channel

Testing the DS0 Management Channel

After the DS0 management channels has been setup with one Remote Axxius, test the
management channel.

1. PING 192.168.202.1 (Axxius1) from the Axxius Router.

2. PING 192.168.202.1 (Axxius1) from the Navigator.

3. PING 192.168.202.1 from the PC.

4. Telnet 192.168.202.1 from the PC to the Remote Axxius.

Once the Management Channel is working properly, add additional Remote units. Test
the DS0 Management Channel after each additional unit has been setup.

With the successful completion of the setup and test of the DS0 Management Channels,
the Ethernet may be reattached to the network.