Features, Technical specifications, Controller software and hardware required – Carrier Access Network Device Axxius 800 User Manual

Page 387: Fxo transmission performance, Features -3 technical specifications -3

Advertising
background image

Axxius 800 - Release 2.2

8-3

FXO

Voice

Card

Features

Features

l

Delivers FXO or DID telephone services from T1 access circuits

l

Supports CLASS services including caller ID, calling party disconnect and
distinctive ringing

l

Provides up to 64 FXO or DPT voice lines in one Axxius 800 chassis, occupying
just two rack units of equipment space (19 or 23- inch rack)

l

Complies with NEBS Level 3 standards for loop range and ringing protection for
end office and customer premises

l

Offers fuseless overvoltage and overcurrent protection to minimize service calls
from lightning and power cross incidents

Technical Specifications

Controller Software and Hardware Required

l

Release 1.1 or higher is required for the FXO Service card

l

-48V NI48V Power Supply (P/N 740-0084) is required for this card

FXO Transmission Performance

l

Return Loss: ERL > 26 dB, SRL > 18 dB with respect to 900

Ω + 2.16µ

F

l

Transhybrid Loss: ERL > 26 dB, SRL > 18 dB with respect to 900

Ω + 2.16µ

F

l

Idle Noise: A/D < 16 dBrnC0, D/A, 12 dBrnC0

l

Crosstalk Coupling: < 70 dB at 0 dBrn0

l

Signal/Distortion: > 35 dB with 1004 Hz, 0 dBm0 input

l

Overload: +3.0 dBm/900

l

Frequency Response: +0.3 dB -1.0 dB from 300 to 3400 Hz

l

Encoding:

µ

-law 255 for U.S. and Canada as defined in CCITT G.711 and G.712

l

Terminating Impedance: 900

+

2.16µ

F

l

Transmit Gain/Loss: +7 to -9 dB, CLI selectable

l

Receive Gain/Loss: +7 to -9 dB, CLI selectable

l

Modem Support: Full compatibility with V.90 modems

Advertising