Set ethernet ip address, Set external alarm, Set ethernet ip address -86 – Carrier Access Network Device Axxius 800 User Manual

Page 186: Set external alarm -86, See the set ethernet ip address, Set ethernet ip address com

Advertising
background image

5-86

Axxius 800 - Release 2.2

CLI Commands

set

set ethernet ip address

Use the set ethernet ip address command to set the Ethernet address for the Axxius 800.

Syntax:

set ethernet ip address {ip-addr} [mask]

Example:

set ethernet ip address 172.26.100.25 255.255.255.0

{ip-addr}

Set the IP address for the Axxius 800, using the form xxx.xxx.xxx.xxx, where xxx is a
number from 0 to 255.

[mask]

Set the subnet mask, using the form xxx.xxx.xxx.xxx, where xxx is a number from 0 to 255.
This is an optional setting.

set external alarm

Use the set external alarm command to set the external alarm inputs.

Syntax:

set external alarm {alarm-num}

{[severity]|[description]}

Example:

set external alarm 1 "test"

The example will set the external alarm #1 description name to "test".

Example:

set external alarm 2 major

The example will set the external alarm #2 severity level to major.

Example:

set external alarm 3 critical "test2"

The example will set the external alarm #3 severity level to critical, with a
description name of "test2".

{alarm-num}

Set the alarm number to configure, range is 1-10.

[severity]

Set the alarm severity level to the following:

critical

Set the external alarm severity level to critical

info

Set the external alarm severity level to information

minor

Set the external alarm severity level to minor

major

Set the external alarm severity level to major

Advertising