4-6

Axxius 800 - Release 2.2

Configuration

Basic System Setup

Set Up a DS0/Channel

Use the following commands to set up a DS0.

Set Up a DS1/T1

Use the following commands to set up a DS1/T1. See the set (ds1) command for more
details.

Command

Description

set {ds0-addr} type

{data|voice}

Set the channel type. See set (ds0) command
for details.

set {ds0-addr} signal

{ls|gs|emw|emdw|emi|emicpd}

Set the signaling option for the channel. See
set (ds0)
command for details.

Command

Description

set {ds1-addr} up

Activate the port.

set {ds1-addr} fdl

{none|t1403}

Set the Facilities Data Link (FDL)
capabilities.

set {ds1-addr} framing

{d4| esf}

Set the framing option for the DS1.

set {ds1-addr} id

{"id-name"}

Set the circuit identification name for the
DS1.

set {ds1-addr} lbo {1-8}

Set the line buildout value for the DS1.

set {ds1-addr} linecode

{ami|b8zs}

Set the linecode for the DS1.

set {ds1-addr} loopdetect

{on|off}

Set the detection/reaction to CSU
loopcodes.

set {ds1-addr} threshold

{day|min15} {bes|css|dm|es

|lcv|les|pcv|sefs|ses|uas)

Set default thresholds for the DS1.