Alarms, Test alarm, Identify alarm – Carrier Access Network Device Axxius 800 User Manual

Page 512

Advertising
background image

C-2

Axxius 800 - Release 2.2

Loopback Tests

Alarms

Alarms

Test Alarm

The Axxius 800 alarm functions can be manually tested using the following command
for setting critical, major and minor alarms. Turning alarms on or off will produce
alarm messages and log entries stating the alarm event was manually set/cleared by the
user.

Syntax:

set alarms {critical|major|minor} {off|on}

Identify Alarm

Alarm indicators

l

LEDs - When an Alarm is triggered, the LED will display a red/yellow

indicator light, which will stay on until the Alarm is cleared. The following
is the LED information for the Control Panel Interface card. For LED
information for a specific service card see the chapter for that card

.

LED

State

Description

CRITICAL

Off

No critical alarms present

Red

Critical alarms present

MAJOR

Off

No major alarms present

Red

Major alarm present

MINOR

Off

No minor alarms present

Red

Minor alarms present

ACO

Off

Normal mode. No alarms are being
suppressed.

Red

Alarm cutoff active. One or more active
alarms suppressed.

Advertising