Set cclabel, Set clock, Set cclabel -74 – Carrier Access Network Device Axxius 800 User Manual

Page 174: Set clock -74, E set clock

Advertising
background image

5-74

Axxius 800 - Release 2.2

CLI Commands

set

set cclabel

Use the set cclable command to set a user defined cross-connect label.

Syntax:

set cclabel {addr} {"label"}

Example:

set cclabel a:1:1 "Idle Ch"

The example will set a user connect label "Idle Ch" on the DS0 a:1:1.

{addr}

{label}

The user defined label can be up to 8 characters, and must be enclosed in quotes.

set clock

Use the set clock command to configure signal clock switching.

Syntax:

set clock {nonrevertive|revertive|switch}

Example:

set clock nonrevertive

The example set the signal clock to nonrevertive mode.

{nonrevertive|revertive|switch}

ds0-addr

In the form of {slot:port|slot:port:channel}.

fxsPS-addr

In the form of {slot:port}.

fxsPSM-addr

In the form of {slot:port}.

tsr_trunk-addr

In the form of {slot:port:channel}.

v35-addr

In the form of {slot:port}.

nonrevertive

Nonrevertive mode, meaning that the clock will not switch back to a
recently failed clock once that clock is restored

revertive

Revertive mode, the clock will automatically switch back and forth, if
possible, to a known good clock signal source

switch

Force a signal clock switch-over. Allows the user to manually switch
from the primary clock to the secondary clock, and vice versa. Clock
source must be healthy for a switch to take place. This command is
not valid in revertive mode.