Set (v54), Set (v54) -172 – Carrier Access Network Device Axxius 800 User Manual

Page 272

Advertising
background image

5-172

Axxius 800 - Release 2.2

CLI Commands

set

set (v54)

Use the set (v54) command to setup V.54 Loopback Test Parameters. The command specifies
the range of channels within that card, and the setting to apply.

Syntax:

set {v54-addr} v54 {setting} [off|on] [n] [nnn]

Example:

set 6:1 v54 equipment clear

The example will clear the loop test counter on the V.54 card in slot 6, port 1.

{v54-addr}

In the form of {slot:port}.

{setting}

slot

Slot number (1-8) of the Axxius chassis where the V.35/54 card is located

port

Port number or range.

equipment

Set the V.54 Equipment (Tx) parameters:

address

Syntax: set {v54-addr} v54 equipment address {nnn}

Set V.54 loop test address [nnn]
Set the address to be tested.
[nnn] {nnn} must be one of the following:
0 - 255.1, 3, 5, 7, 9, 11, 13, 15,17, 19, 21, 23, 25, 27, 29, 31, 37, 39,
43, 45, 47, 51, 53, 55, 59, 61, 63, 85, 87, 91, 95, 111, 119, 127, 255
(255 disables). See chart below.

clear

Syntax: set{v54-addr} v54 equipment clear

Clear the bit error rate counters during BER test

ignoreack

Syntax: set{v54-addr} v54 equipment ignoreack

{off|on}

Ignore V.54 ACK check [off|on]
Ignore acknowledge from remote equipment. This allows potential
testing with non-compliant equipment by ignoring the acknowledge
phase. WARNING: When choosing this option, the V.35 card
will no longer be compliant with the V.54 specification. Use for
debug purposes only.

loopdown

Syntax: set{v54-addr} v54 equipment loopdown

Stop the test sequence

loopup

Syntax: set{v54-addr} v54 equipment loopup

Start the test sequence