Carrier Access Network Device Axxius 800 User Manual

Page 99

Advertising
background image

Axxius 800 - Release 2.2

4-27

Configuration

Setup of DS0 Management Channel

Configuration of Access Navigator

Note: The Ethernet cannot be connected to the Remote Axxius during the
setup of the DS0.

The following setup, creates a path from the Axxius Router to the remote Axxius.

Note: the following commands are assuming that the Access Navigator is set
to factory defaults.

Command

Description

set ds1 1-32 down

Sets 1-32 Out-of-Service

set ethernet ip address

192.168.201.100

255.255.255.0

Sets the Ethernet IP address of the Navigator and it’s
subnet mask

set ip gateway

192.168.201.101

Sets the gateway (router address)

set ds1 32 type groom

Sets DS1 32 to groom

set ds0 32:1-24 type data

Sets DS0 32 1-24 to data signaling type

set ds1 1 remote device

mgmt caip 192.168.202.1

Sets DS1 1 as the Management Channel with the Router
(address listed)

set ds0 1:24 type data

Sets DS0 1-24 to data signaling type

connect 1:24 32:1

Connects DS1 1:DS0 24 to DS1 32, DS0 1

set ds1 32 up

Sets DS1 32 In Service

set ds1 1 up

Sets DS1 1 In Service

set snmp nms1

xxx.xxx.xxx.xxx

Sends alarms to server. xxx.xxx.xxx.xxx is the IP
Address of the server.

show ds1 1

Displays DS1 1 information

show ip

Displays IP Address information

show connect 1

Displays connections on DS1 1

status remote 1

Displays the status of the Management Channel

Advertising