Carrier Access Network Device Axxius 800 User Manual

Page 179

Advertising
background image

Axxius 800 - Release 2.2

5-79

CLI Commands

set

id

Set the DS1 circuit identification name. This is the same as dsx1Circuit
Identifier from DS1 MIB transmission vendor’s identification. String
text must be enclosed in quotes

.

Example: set {ds1-addr} id {"id-name"}

{id-name} = transmission vendor’s ID, up to 30 characters, in quotes.

lbo

Set the Line Build Out (LBO) to one of the following: Note: this
options is not applicable on a DS1 within a DS3.

1

DSX-1 equalization for 0-133 feet (equivalent to CSU
attenuation for LBO of 0dB)

2

DSX-1 equalization for 133-266 feet

3

DSX-1 equalization for 266-399 feet

4

DSX-1 equalization for 399-533 feet

5

DSX-1 equalization for 533-655 feet

6

CSU attenuation for LBO of -7.5dB

7

CSU attenuation for LBO of -15dB

8

CSU attenuation for LBO of -22.5dB

line

Turn a line loopback to the DS1 interface on or off. If the line command
is not used, the default for line loopback is loopdown.

loopdown

Disable the line loopback

loopup

Enable a DS1 line loopback toward the DS1 drop

linecode

Set the DS1 interface line coding to one of the following. If the linecode
command is not used, the default for linecode is B8ZS.
Note: this options is not applicable on a DS1 within a DS3.

ami

Alternate Mark Inversion line coding

b8zs

Binary 8 Zero Substitution line coding.

loopdetect

Enable detection of CSU loop code (10000 - loopup; 100 - loopdown)

on

Enable detection

off

Disable detection

payload

Apply a payload loopback to the DS1 interface. If the payload
command is not used, the default for payload loopback is loopdown.

loopdown

Disable the payload loopback

loopup

Enable the payload loopback