Axxius 800 - Release 2.2

11-3

Single Channel POTS Cards

Technical Specifications

Technical Specifications

Controller Software Required

l

Release 1.0 or higher is required for the POTS Service cards

FXS Transmission Performance

l

Return Loss: ERL > 28 dB, SRL > 20 dB with respect to 900

Ω + 2.16µ

F

l

Transhybrid Loss: ERL > 28 dB, SRL > 20 dB with respect to 900

Ω + 2.16µ

F

l

Idle Noise: A/D < 25 dBrnC0

l

Signal/Distortion: > 45 dB with 1004 Hz, 0 dBm0 input

l

Terminating Impedance: 900

+

2.16µ

F

l

Transmit Gain/Loss: +4 to -12 dB (in .25 increments)

l

Receive Gain/Loss: +4 to -12 dB (in .25 increments)

l

Overload: +3.0 dBm0

l

Frequency Response: +0 dB -1.0 dB from 300 to 3400 Hz

l

Longitudinal Balance: >50 dB

l

Modem support: full compatibility with V.90 modems

Modem Performance

l

The Single Channel POTS card modem is registered for direct connection to the
PSTN

FXS Signaling Performance

l

DC Loop Range: 512

l

Loop Feed: Nominal -48 VDC with 26mA current limit

l

Ringing Voltage: 40 V rms, 20 Hz

l

Maximum Ringers: 2 REN, FCC Class B ringers

l

FXS Signaling: FXS loop start