Axxius 800 - Release 2.2

7-9

DS3

Controller

Card

Controller and DS3 Redundancy

switching the output paths so that the transmit path of the DS3 line is connected to the
standby Controller. Service interruptions (hits) will be taken on both the DS3 and low-
speed connections during this type of switch. However, since the standby Controller is
already framed up to the incoming signal, the hits are minimal.

The Axxius does not provide a non-revertive mode in electronic protection. No
automatic switchback will occur (as with a revertive Network Protection), but if the
currently active Controller malfunctions, etc. another protection switch will occur if the
mate is in a standby mode.

Active

(Primary)

M13 Mux

Controller

DS3OUT+

DS3IN+

28/21 LS

XMT Stream

28/21 LS

RCV Stream

xmt

rcv

Primary

DS3

Electronics Protection Mode

Standby

(Secondary)

M13 Mux

Controller

DS3OUT+

DS3IN+

28/21 LS

RCV Stream

28/21 LS

XMT Stream

Controller

Select

Disable

Enable

Electronics Protection Mode of the Axxius DS3