Line rates/line lengths, Line rates/line lengths -12 – Carrier Access Network Device Axxius 800 User Manual

Page 412

Advertising
background image

10-12

Axxius 800 - Release 2.2

OCU-DP Card

Line Rates/Line Lengths

Line Rates/Line Lengths

All lengths were measured to meet a BER of 10

-7

with up to 45 dB of cable attenuation

at the Nyquist frequency for 56, 64 and 72 Kbps, and 40 dB all other rates.

Service Data
Rate

Primary Channel /
Secondary Channel

Max. Loop Distance (24 AWG)
Primary Channel only/Primary &
Secondary Channel

2.4 Kbps

2.4 Kbps/3.2 Kbps

13.8 miles/12.7 miles

(22.3 km/20.4 km)

4.8 Kbps

4.8 Kbps/6.4 Kbps

11.0 miles/10.0 miles

(17.7 km/16.1 km)

9.6 Kbps

9.6 Kbps/12.8 Kbps

8.0 miles/13.3 miles

(13.0 km/12.2 km)

19.2 Kbps

19.2 Kbps/25.6 Kbps

6.3 miles/5.9 miles

(10.1 km/9.4 km)

38.4 Kbps

38.4 Kbps/51.2 Kbps

5.5 miles/5.3 miles

(8.8 km/8.5 km)

56 Kbps

56 Kbps/72 Kbps

5.1 miles/4.7 miles

(8.2 km/7.6 km)

64 Kbps

64 Kbps

4.7 miles

(7.6 km)