Alarms, Testing and diagnostics, Power consumption – Carrier Access Network Device Axxius 800 User Manual

Page 369: Environment, Physical

Advertising
background image

Axxius 800 - Release 2.2

6-7

DS1 Controller Card

Technical Specifications

Alarms

l

Three visible alarm outputs, critical, major and minor

l

Three audible alarm outputs, critical, major and minor

l

Alarm Cut-Off for audible alarm outputs

l

Ten external alarm inputs (user definable)

l

Alarm contacts accessible from external alarm connector

l

All alarms are logged in an event log

l

Loss of power triggers minor alarm

l

Generates SNMP traps for alarming (MIB objects)

Testing and Diagnostics

l

Standard T1 line and payload loopbacks

l

Local loopback

l

T1.231 performance history

Power Consumption

l

6 W maximum

Environment

In addition to the systems environment requirements, the following applies to the
DS1 Controller card. For additional information see Installation Environment” on
page 2-3.

l

Operating temperature range of the DS1 Controller card: -40

°

to 149

°

F

(-40

°

to 65

°

C)

Physical

l

Dimensions: 3.5 in. (H) x 0.75 in. (W) x 11.25 in. (D)
8.9 cm (H) x 1.9 cm (W) x 28.6 cm (D)

l

Weight: 10.2 oz. (0.29 kg)

Advertising