16-3

V.35/.54 Card

Features

Features

l

Each port provides any n x 56/ 64 Kbps data rate up to 1.536 Mbps on each port

l

Full non-blocking cross-connection of all timeslots to any T1 access line

l

Up to 16 V.35 ports may be equipped in a single Axxius 800 platform

l

Supports adaptation and tansport over TDM facilities

Additional V.54 Features

l

V.54 Loop Test capability

Technical Specifications

Controller Software Required

l

Release 1.0 or higher is required for the V.35/54 service card

Service Interface

l

Two V.35 interfaces:

-

Configured as DCE

-

Two sub-miniature DB-26 connectors

-

DB26 to V.35 adapter cables available

Network Interface

l

T1 N x DS0, where N = 1-24

Clocking

l

Looped-timed from any T1 card installed

l

Sources clock to the DTE device