IAI America XSEL-KE User Manual

Page 118

Advertising
background image

103

Part 4 Commands

z BTPF (Output OFF pulse)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

BTPF

Output

port, flag

Timer

setting

CP

[Function]

Turn OFF the specified output port or flag for the specified time.
When this command is executed, the output port or flag specified in operand 1 will be turned
OFF and then the program will proceed to the next step. The output port or flag will be
turned ON automatically upon elapse of the timer setting specified in operand 2.
The timer is set in a range from 0.01 to 99.00 seconds (including up to two decimal places).

(Note 1)

If this command is executed with respect to an output port or flag already OFF, the output
port or flag will be turned ON upon elapse of the timer setting.

(Note 2)

If the program ends after the command has been executed but before the timer is up, the
output port or flag will not be turned ON.

(Note 3)

This command will not be cancelled by a TIMC command.

(Note 4)

A maximum of 16 timers, including BTPN and BTPF, can be operated simultaneously in a
single program. (There is no limitation as to how many times these timers can be used in a
single program.)

[Example]

BTPF

300

1

Turn OFF output port 300 for 1 second.

BTPF

600

10

Turn OFF flag 600 for 10 seconds.

Timer setting (seconds)

The output port or flag turns OFF here, after
which the program will proceed to the next step.

ON

OFF