2. Parameters Common to All Axes

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

1

Effective axis pattern

0000B

00B ~

11111111B

2

Default override

100

1 ~ 100

Used if not specified in program. (Invalid for SIO operation)

3~8 (For

expansion)

0

9 Deadman-switch

enabling physical
axis pattern

11111111B 00B

~

11111111B

Not affected by a BASE command. (Always specify
11111111 if all axes are used. If not, the servo may be
turned off only for the specified axes without cutting off
the drive source (7-segment LED display does not
VKRZ³'6)´  
* The drive-source cannot be cut off for axes whose

motor-drive power unit is not housed inside this
controller or whose drive-source cutoff circuit is not
controlled by this controller.

* If an optional (custom) specification is used, the

optional (custom) specification takes precedence
over the deadman switch enabling physical
axis/drive-source cutoff specification, servo OFF
specification, 7-segment display specification, etc.

10 (For

expansion)

0

11 Default acceleration

30

1 ~ 200

0.01 G Used if not specified in position data, program or SIO

message, etc.

12 Default deceleration

30

1 ~ 200

0.01 G Used if not specified in position data, program or SIO

message, etc.

13 Default speed

30

1 ~ 250

mm/s

Used if not specified in SIO message or position data,
when movement is to be continued, etc.

14 Valid selection when

operation point data
deceleration is 0



a



 ³'HFHOHUDWLRQ $FFHOHUDWLRQ´ZKHQWKHGHFHOHUDWLRQ

LQWKHRSHUDWLRQSRLQWGDWDLV³´

 ³'HFHOHUDWLRQ ´Zhen the deceleration in the

RSHUDWLRQSRLQWGDWDLV³´

15 Maximum jog speed

when home return is
incomplete

30

1 ~ 250

mm/s

16~

19

(For expansion)

0

~

20 Maximum

operating

speed check timing

1

0 ~ 1

0: Check at input
1: Check at operation

 ,I³&KHFNDWRSHUDWLRQ´LVselected, the distribution

speed (CP) of specified speed or the specified
speed (PTP) will be compared against the
maximum operating speed of each axis and
clamped at the allowable speed. Accordingly, the
system can achieve its maximum performance in
accordance with the operation command.
However, complete check cannot be performed
at input (since the command/operation start
position is indeterminable). In the case of CP, the
distribution speed will vary depending on the
operation start position. Therefore, specifying CP
at an unspecified position (first point movement,
etc.) will cause the speed to fluctuate depending
on where the operation is started.

21 Maximum

operating

speed for input value
check



a

PPV

,I³,QSXW´LVVHOHFWHGDVWKHPD[LPXPVSHHGFKHFN
timing, this parameter will be used to check for input
error.

22 Maximum

acceleration

100

1 ~ 999

0.01 G

23 Maximum

deceleration

100

1 ~ 999

0.01 G

24 Minimum

emergency

deceleration

30

1 ~ 300

0.01 G

25 (Acceleration/deceler

ation at home return
(old))

30

1 ~ 300

0.01 G (Valid only with main application version 0.40 or earlier)

Advertising
This manual is related to the following products: