IAI America XSEL-KE User Manual

Page 267

Advertising
background image

252

Part 4 Commands

(4) Simple program example using PASE, PAPT and PAST

The example below specifies movement only and does not cover picking operation.

Step

E

N

Cnd

Cmnd

Operand 1

Operand 2

Pst

Comment

1

BGPA

1

Start setting palletizing No. 1.

2

3

PAPI

5

7

Palletizing counts: 5 x 7

4

PAPN

1

Palletizing pattern 1

5

PASE

1

2

PX-axis = Axis 1, PY-axis = Axis 2

6

PAPT

40

30

Pitch (X = 40 mm, Y = 30 mm)

7

PAST

1

Set reference point data.

8

Use position No. 1 data.

9

PSLI

20

4

Zigzag offset = 20 mm

10

Zigzag count = 4

11

PCHZ

3

Palletizing Z-axis = Axis 3

12

PTRG

4

4

Set palletizing arch triggers.

13

Use position No. 4 data.

14

OFPZ

100

PZ-axis offset = 100 mm

15

16

EDPA

17

18

* / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /

19

ATRG

4

4

Set arch triggers.

20

Use position No. 4 data.

21

ACHZ

3

Set arch-motion Z-axis.

22

23

ACC

0.3

Acceleration

24

DCL

0.3

Deceleration

25

VLMX

26

27

PSET

1

1

Set palletizing position number.

28

MOVP

8

Move to picking position.

29

* / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /

30

Advertising