79 part 4 commands – IAI America XSEL-KE User Manual

Page 94

Advertising
background image

79

Part 4 Commands

Operation type in the output field
CC: Command was executed successfully, ZR: Operation result is zero,
PE: Operation is complete, CP: Command part has passed, TU: Time up
EQ: Operand 1 = Operand 2, NE: Operand 1

z Operand 2,

GT: Operand 1 > Operand 2, GE: Operand 1

t Operand 2,

LT: Operand 1 < Operand 2, LE: Operand 1

d Operand 2

Category

Condition Command

Operand 1

Operand 2

Output

Function

Page

Optional

AXST

Variable number

Axis number

CP

Get axis status

187

Optional

PGST

Variable number

Program number

CP

Get program status

188

System

information

acquisition

Optional

SYST

Variable number

Prohibited

CP

Get system status

189

Optional

WZNA

Zone number

Axis pattern

CP

Wait for zone ON, with AND

190

Optional

WZNO

Zone number

Axis pattern

CP

Wait for zone ON, with OR

191

Optional WZFA Zone

number

Axis pattern

CP

Wait for zone OFF, with AND

192

Zone

Optional

WZFO

Zone number

Axis pattern

CP

Wait for zone OFF, with OR

193

Optional OPEN Channel number

Prohibited

CP Open

channel

194

Optional

CLOS

Channel number

Prohibited

CP

Close channel

194

Optional

READ

Channel number

Column number

CC

Read from channel

195

Optional

TMRD

Timer setting

Prohibited

CP

Set READ timeout value

196

Optional

WRIT

Channel number

Column number

CP

Output to channel

197

Communica

tion

Optional

SCHA

Character code

Prohibited

CP

Set end character

198

Optional SCPY Column

number

Column number,
character literal

CC

Copy character string

199

Optional SCMP Column

number

Column number,
character literal

EQ

Compare character strings

200

Optional SGET Variable

number

Column number,
character literal

CP Get

character

201

Optional

SPUT

Column number

Data

CP

Set character

202

Optional STR Column

number Data

CC

Convert character string;
decimal

203

Optional STRH Column

number Data

CC

Convert character string;
hexadecimal

204

Optional VAL Variable

number

Column number,
character literal

CC

Convert character string data;
decimal

205

Optional VALH Variable

number

Column number,
character literal

CC

Convert character string data;
hexadecimal

206

1201

199

Optional

SLEN

Character string length

Prohibited

CP

Set length

207

Advertising
This manual is related to the following products: