IAI America XSEL-KE User Manual

Page 236

Advertising
background image

221

Part 4 Commands

z ATRG (Set arch triggers)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

ATRG

Position

number

Position

number

CP

Set the arch triggers used for arch motion.
(This setting becomes valid when an ARCH command is executed.)
Set the arch-motion Z-axis position data in the point data specified in operand 1 as the start-point arch
trigger, and set the arch-motion Z-axis position data in the point data specified in operand 2 as the end-
point arch trigger.

ATRG 13 11

5HIHUWR³3DOOHWL]LQJ6HWWLQJ´±³$UFKWULJJHUV´XQGHU³+RZWR8VH´ 
)RUDQDUFKPRWLRQRSHUDWLRQVHWLWVRWKDWDKRUL]RQWDOPRYHPHQWZLOOEHJLQZKHQWKHVWDUWSRLQWDUFK
trigger is reached during ascent from the start point, and that the end-point arch trigger will be reached
DIWHUDKRUL]RQWDOPRYHPHQWLVFRPSOHWHGGXULQJGHVFHQW
If the output field is specified, the output will turn ON after this command is executed.

Start-point arch trigger

Position No. 13

End-point arch trigger
Position No. 11

Start point

End point