331

Appendix

I/O Parameters

No.

Parameter

name

Default value

(Reference)

Input

range

Unit

Remarks

33 Input

function

selection 003

1

0 ~ 5

0: General-purpose input
1: General-purpose input (Start the auto-start program upon

power-ON reset/software reset in the AUTO mode)

2: Auto-start program start signal (ON edge: Start, OFF edge:

Abort all operations/programs (excluding the I/O
processing program at operation/program abort)) * If this
parameter is used as an auto-start program start signal,
turn ON the signal for at least 100 msec so that the
program will start without fail.

34 Input

function

selection 004

0

0 ~ 5

0: General-purpose input
1: All servo axis soft interlock (OFF level) (Valid for all

commands other than the servo OFF command)
(Operation is held upon interlock actuation during
automatic operation; operation is terminated upon interlock
in non-AUTO mode)

35 Input

function

selection 005

0

0 ~ 5

0: General-purpose input, 1: Operation-pause reset signal

(ON edge)

36 Input

function

selection 006

0

0 ~ 5

0: General-purpose input
1: Operation-pause reset signal (OFF level) (Valid only during

automatic operation)

* Cancel pause when an operation-pause reset signal is

received.

37 Input

function

selection 007

1

0 ~ 5

0: General-purpose input, 1: Program number specified for

program start (least significant bit)

38 Input

function

selection 008

1

0 ~ 5

0: General-purpose input, 1: Program number specified for

program start

39 Input

function

selection 009

1

0 ~ 5

0: General-purpose input, 1: Program number specified for

program start

40 Input

function

selection 010

1

0 ~ 5

0: General-purpose input, 1: Program number specified for

program start

41 Input

function

selection 011

1

0 ~ 5

0: General-purpose input, 1: Program number specified for

program start

42 Input

function

selection 012

1

0 ~ 5

0: General-purpose input, 1: Program number specified for

program start

43 Input

function

selection 013

1

0 ~ 5

0: General-purpose input
1: Program number specified for program start
2: Error reset (ON edge)

44 Input

function

selection 014

0

0 ~ 5

0: General-purpose input (Cancel cutoff when the drive-

source cutoff factor is removed)

1: Drive-source cutoff reset input (ON edge) (Valid when the

factor has been removed)

* Drive-source cutoff reset control is not available for axes

whose motor-drive power unit is not housed inside this
controller or whose drive-source cutoff circuit is not
controlled by this controller.

45 Input

function

selection 015

0

0 ~ 5

0: General-purpose input
1: Home return of all valid axes (ON edge) (Servo ON must

be executed first = I/O parameter No. 32, Axis-specific
parameter No. 13)

2: Home return of all valid incremental axes (ON edge) (Main

application version 0.16 or later) (Servo ON must be
executed first = I/O parameter No. 32, Axis-specific
parameter No. 13)

46 Output

function
selection 300

2

0 ~ 20

0: General-purpose output
1: Output error of operation-cancellation level or higher (ON)
2: Output error of operation-cancellation level or higher (OFF)
3: Output error of operation-cancellation level or higher +

emergency stop (ON)

4: Output error of operation-cancellation level or higher +

emergency stop (OFF)

Advertising