I/o parameters – IAI America XSEL-KE User Manual

Page 343

Advertising
background image

328

Appendix

1. I/O Parameters

No. Parameter

name

Default value

(Reference)

Input

range

Unit

Remarks

1

I/O port assignment
type

1

0 ~ 20

0: Fixed assignment
1: Automatic assignment (Priority: Slot 1 (standard I/O) ~ * Ports

are assigned only for the installed adjoining slots, starting from
slot 1 = For safety reasons)

2

Input port start
number with fixed
standard I/O
assignments (I/O1)

000

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set)

3

Output port start
number with fixed
standard I/O
assignments (I/O1)

300

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

4

Input port start
number with fixed
expanded I/O1
assignments (I/O2)

-1

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set) (Slot next to the
standard I/O slot)

5

Output port start
number with fixed
expanded I/O1
assignments (I/O2)

-1

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

6

Input port start
number with fixed
expanded I/O2
assignments (I/O3)

-1

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set)

7

Output port start
number with fixed
expanded I/O2
assignments (I/O3)

-1

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

8

Input port start
number with fixed
expanded I/O3
assignments (I/O4)

-1

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set)

9

Output port start
number with fixed
expanded I/O3
assignments (I/O4)

-1

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

10 Standard I/O error

monitor (I/O1)

1

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O power source)

(Main application version 0.55 or later)

3: Monitor (Monitor only errors relating to 24-V I/O power source)

(Main application version 0.55 or later)
* Some exceptions apply.

11 Expanded I/O1 error

monitor (I/O2)

1

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O power source)

(Main application version 0.55 or later)

3: Monitor (Monitor only errors relating to 24-V I/O power source)

(Main application version 0.55 or later)
(Slot next to the standard I/O slot) * Some exceptions apply.