I/O Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

12 Expanded I/O2 error

monitor (I/O3)

1

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to

24-V I/O power source)
(Main application version 0.55 or later)

3: Monitor (Monitor only errors relating to 24-V

I/O power source)

(Main application version 0.55 or later)

* Some exceptions apply.

13 Expanded I/O3 error

monitor (I/O4)

1

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to

24-V I/O power source)
(Main application version 0.55 or later)

3: Monitor (Monitor only errors relating to 24-V

I/O power source)

(Main application version 0.55 or later)

* Some exceptions apply.

14 Number of ports

using network-I/F-
card remote input

0

0 ~ 256

Refer to the operation manual for each
network I/F card (CC-Link, DeviceNet, etc.).

15 Number of ports

using network-I/F-
card remote output

0

0 ~ 256

Refer to the operation manual for each
network I/F card (CC-Link, DeviceNet, etc.).

16 (For future expansion

= Change prohibited)

0

0 ~ 256

Multiple of 8

17 (For future expansion

= Change prohibited)

0

0 ~ 256

Multiple of 8

18~

19

(For expansion)

0

20 Input filtering periods

2

1 ~ 9

msec Input signal is recognized when the status is

held for twice the period set by this parameter.

21 Register input filtering

periods

2

1 ~ 9

msec Input signal is recognized when the status is

held for twice the period set by this parameter.

22 Remote-I/O-card

fieldbus ready
timeout value



a

PVHF 7LPHRXWFKHFNLVQRWSHUIRUPHGLI³´LVVHW

23 Overcurrent/power-

supply error detection
input specification for
multi-point DIO
external terminal
block

0H 0H

~

FFFFFFFFH

Bits 0 to 3:

For future expansion

Bits 4 to 7:

Expanded I/O1 (I/O2) input
specification

Bits 8 to 11:

Expanded I/O2 (I/O3) input
specification

Bits 12 to 15: Expanded I/O3 (I/O4) input

specification

(0: Do not use error detection input

1: Use error detection input = IN023 on card
2: Use error detection input = IN047 on card
3: Use error detection input = IN023/47 on card)

* Determine an appropriate setting after

checking the specification of the multi-point
DIO terminal block unit to be connected.

* The input port used for the error detection

input cannot be used as a general-purpose
input port.

* If the main application version is 0.82 or

HDUOLHUEHVXUHWRVSHFLI\³ 'RQRWXVH
HUURUGHWHFWLRQLQSXW ´