42

Part 1 Installation

Chapter 8 Maintenance

x Routine maintenance and inspection are necessary so that the system will operate properly at all

time. Be sure to turn off the power before performing maintenance or inspection.

x The standard inspection interval is six months to one year. If the environment warrants, however, the

interval should be shortened.

(1) Inspection points

x Check to see if the supply voltage to the controller is inside the specified range.
x Inspect the ventilation holes in the controller and remove dirt, dust and other foreign attachments, if

any.

x Inspect the controller cables (controller o actuator) and check for any loose screws or cable

disconnection.

x Check the controller mounting screws, etc., for looseness.
x Inspect each cable (axis link cable, general-purpose I/O cable, system I/O cable, power cable) for

loose connection, disconnection, play, etc.

(2) Spare consumable parts

Without spare parts, a failed controller cannot be repaired even when the problem is identified quickly.
We recommend that you keep the following consumable parts as spares:

Consumable parts

x Cables
x System-memory backup battery: CR2032 (Note)
x Absolute-data backup battery: IA-XAB-BT by IAI

*: The actual battery life will vary depending on the use condition.

Use condition

Temperature: 40

qC

Time power is
supplied: 0%

Temperature: 40

qC

Time power is
supplied: 50%

CR2032 (Note)

1.5 years

3 years

IA-XAB-BT by IAI

1 year

2 years

(Note ): CR2032 is a standardized product and can be used with products by any manufacture.

x Fuses

Memory backup
The X-SEL Controller saves program, position and parameter data to its flash memory (when written to
the flash memory). The data saved by the battery are positions, SEL global data and error lists. (Refer
WR&KDSWHU³+RZWR6DYH'DWD´RI3DUW 

When the battery voltage drops, an applicable error code will be displayed on the panel window.

Error Codes Indicating Low Battery Voltage

System-memory backup battery (CR2032)

A01 or A02

Absolute-data backup battery (IA-XAB-BT)

A03 or A23

In the case of a low battery voltage of the absolute-

GDWDEDFNXSEDWWHU\WKHD[LVGULYHUVWDWXV/('ZLOO

also illuminate.