IAI America XSEL-KE User Manual

Page 31

Advertising
background image

16

Part 1 Installation

(17) PC connector

(general-purpose type
only)

This D-sub, 9-pin connector is used to perform serial communication
(RS232C) with the host equipment when AUTO is selected as the
operation mode.

* (16) and (17) cannot be used simultaneously.

RS232 Host Connector Specifications

This connector is used to establish a serial connection with a PC or PLC to enable
controller control.

n

o

i

t

p

i

r

c

s

e

D

m

e

t

I

Connector name

HOST

Connector

D-sub, 9-pin (DTE); XM2C-0942-502L by Omron

Maximum
connection
distance

10 m (38.4 kbps)

Interface standard RS232C

Connected to

AT-compatible PC, etc. (half-duplex communication)

Connection cable

Dedicated cable

Pin No.

I/O

Signal name

Description

1

NC

2

In

RD

Received data (RXD)

3

Out

SD

Transmitted data (TXD)

4

In

DR

Data set ready (DSR)

5

In

SG

Signal ground

6

Out

ER

Equipment ready (DTR)

7

Out

RS

Request to send (RTS)

8

In

CS

Clear to send (CTS)

Terminal
assignments

9

NC

Not used

A dedicated cable must be used if an AT-compatible PC is to be
connected.

The PC connector (D-sub, 9-pin) (17) will become available for use by the
user only when the teaching-pendant connector (D-sub, 25-pin) (16) is not
in use.

1

(

)

n

i

p

-

9

,

b

u

s

-

D

(

r

o

t

c

e

n

n

o

c

C

P

e

h

T

7) and teaching-pendant connector (D-

sub, 25-pin) (16) cannot be used simultaneously. Setting the mode switch
(15) to MANU will select the teaching-pendant connector (16), while
setting it to AUTO will select the PC connector (17).

(18) Standard I/O connector

This connector consists of a 50-pin flat connector and comprises 32-
input/16-output DIOs.

Overview of Standard I/O Interface Specifications

n

o

i

t

p

i

r

c

s

e

D

m

e

t

I

Connector name

I/O

Connector

Flat connector, 50-pin

Power supply

With a general-purpose type, power is supplied from the
I/O24V power connector (13).
With a compact type, power is supplied from connector
pin Nos. 1 and 50.

Input

32 points (including general-purpose and dedicated
inputs)

Output

16 points (including general-purpose and dedicated
outputs)

Connected to

External PLC, sensor, etc.

Advertising
This manual is related to the following products: