IAI America XSEL-KE User Manual

Page 171

Advertising
background image

156

Part 4 Commands

z HOME (Return to home)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

HOME

Axis

pattern

Prohibited PE

[Function] Perform home return of the axes specified by the axis pattern in operand 1.

The servo of each home-return axis will turn ON automatically.
The output will turn OFF at the start of home return, and turn ON when the home return is
completed.

(Note)

Following a pause of home return, the operation will resume from the beginning of the home-
return sequence.
Home-return operation of an absolute-encoder axis is a movement to a rotation data reset
position, and may not be a movement to the preset home coordinates (including 0). Use a
MOVP command instead of a HOME command, if you wish to perform home return for the
SXUSRVHRIWXUQLQJ21RXWSXWZKHQ³,2SDUDPHWHU1R2XWSXWIXQFWLRQVHOHFWLRQ´
LVVHWWR³´ 2XWSXWLIDOOYDOLGD[HVDUHDWWKHKRPH  RU³´ 2XWSXWLIDOOYDOLGD[HVDUHDW
the preset home coordinates).
If the operation is stopped or cancelled while a HOME command is being executed for an
absolute-encoder axis in a mode other than the absolute reset mode provided by the PC
VRIWZDUHRUWHDFKLQJSHQGDQWDQ³DFWXDOSRVLWLRQVRIWOLPLWHUURU´PD\JHQHUDWHGHSHQGLQJRQ
the position. It is not recommended to perform home return other than for the purpose of
adjusting an absolute-encoder axis.

[Example 1]

HOME

1100

Axes 3 and 4 return to the home.

[Example 2]

The axis pattern can be specified indirectly using a variable.
When the command in [Example 1] is rephrased based on indirect specification using
a variable:
1100 (binary)

o 12 (decimal)

LET

1

12

Assign 12 to variable 1.

HOME

*1

Advertising
This manual is related to the following products: