Caution – IAI America XSEL-KE User Manual

Page 41

Advertising
background image

26

Part 1 Installation

(2) Output

part

External Output Specifications (PNP Specification)

Item

Specification

Load voltage

24 VDC

Maximum load current 100 mA per point, 400 mA per 8 ports Note)

Leakage current

0.1 mA max. per point

TD62784 (or equivalent)

Isolation method

Photocoupler isolation

External devices

(1) Miniature

relay

(2) Sequencer input unit

Note) 400 mA is the maximum total load current of every eight ports from output port No. 300. (The

maximum total load current of output port No. 300 + n to No. 300 + n + 7 is 400 mA, where n is 0
or a multiple of 8.)

[Output circuit]

*

General

purpose

Compact

P24

I/O24V connector

24V IN

I/O interface pin No. 1

N

I/O24V connector

0V

I/O interface pin No. 50

In the event that the load is short-circuited or a current exceeding the maximum load
current is input, the overcurrent protection circuit will be actuated to cut off the circuit.
However, give due consideration to the circuit connection layout to prevent short-circuit
or overcurrent.

Internal circuit

10

:

N

P24

Surge absorber

Output terminal

Load

External power supply
24 VDC

10%

+

-

Caution

Advertising