22

Part 1 Installation

(2) Type K (General-purpose type)

Type

Type K (General-purpose type)

Number of controlled axes

1 axis

2 axes

3 axes

4 axes

Total output when maximum
number of axes are connected

Power-source voltage 100 V: 800 W

Power-source voltage 200 V: 1600 W

Power-source voltage

Single-phase, 100 to 115/200 to 230 VAC (factory setting)

Operating power-source
voltage range

r10%

Power-source frequency

50 Hz/60 Hz

Isolation resistance

10 M

: min. (measured at 500 VDC between the power terminal and I/O

terminals and between the external terminals (together) and case)

Withstand voltage

1500 VAC for 1 minute (Note)

Surrounding air temperature
range

0

qC to 40qC

Surrounding humidity range

30% to 85%

Storage temperature range

-10

qC to 65qC

Axis control method

AC full digital servo

Position detection methods

17-bit incremental encoder (wire-saving type)

17-bit rotation data backup absolute encoder (wire-saving type)

(Both have a control resolution of 14 bits)

Batteries

For backup of absolute data: IA-XAB-BT by IAI

For backup of system memory: CR2032

Speed setting

1 mm/sec to 2000 mm/sec

Acceleration/deceleration
setting

0.01 G to 1 G

Programming language

Super SEL language

Program steps

6000 steps (total)

Number of positions

3000 positions (total)

Number of programs

64 programs

Multi-tasking 16

programs

Storage device

Flash ROM + SRAM battery backup

Data input methods

Teaching pendant or PC software

Standard inputs

32 points (total of dedicated inputs + general-purpose inputs)

Standard outputs

16 points (total of dedicated outputs + general-purpose outputs)

Expanded inputs/outputs

48 points per unit (a maximum of 3 units can be added)

Serial communication

For connection of teaching pendant or PC

Other inputs/output

Emergency-stop input, safety-gate input, system ready output

Protective functions

Motor overcurrent, overload, motor-driver temperature check, overload

check, encoder-open detection, soft limit over, system error, battery error

Drive-source cutoff method

Relay

Regenerative resistance

Built-in (220

:, 80 W); external regenerative resistance supported

Accessory

I/O flat cable

Optional parts and
components

Teaching pendant, PC software, absolute-data backup battery unit, I/O
shield cable, I/O expansion board

Note: The withstand voltage of the actuator motor is 1000 V for 1 minute.

When performing a withstand voltage test with the controller and actuator connected, make sure the test voltage and
duration will not exceed 1000 V and 1 minute, respectively.

, Type KE (CE-compliant)