IAI America XSEL-KE User Manual

Page 266

Advertising
background image

251

Part 4 Commands

Schematic diagram of placement-point positions based on the above program

x The number shown at the top right of each circle indicates a palletizing position number.
x Count in PX-axis direction = 5, Count in PY-axis direction = 7
x Zigzag offset: 20
x Zigzag count: 4
x Pallet shift angle T±q

Axis-1 direction

End-point coordinates of preferential axis (PX-axis): Position No. 2 (260, 105, 100)

Reference point: Position No. 1
(100, 100, 100)

PY-axis

End-point coordinates of PY-axis: Position No. 3
 

PX-axis

Axis-2 direction

T

5

4

3

2

1

20

14

23

32





27

13

22

31



17

26

12

21

30

7

16

25

11





6

15

24

10





Advertising