INTELLIGENT ACTUATOR

Descripti

on

Action Parameter

setti

ng

Mani

pul

ation/operati

on

Want to exec

ute home retur

n using

an ex

ternal input signal.

Input port No. 15 can be used as an

home retur

n input.

I/O parameter No. 45 = 1

Home return

w

ill be executed at the ON

edge of input port No. 15. (Servo ON

must be execut

ed befor

eh

and.

)

Want to input program numbers from

input ports in binar

y

. (T

he default

setting is BCD

input.)

Program numbers can be input from

input port Nos. 7 to 13 in binar

y.

I/O parameter No. 30 = 2

Want to check the level of the

present error from an output port.

Want to check for emergenc

y

stop

status from an output port.

Error level c

an

be check

ed from the

ON/OFF combination of output port

Nos. 300 and 301.

Emergenc

y

stop status can be

checked from ON/OFF of output port

No. 302.

I/O parameter No. 46 = 2

I/O parameter No. 47 = 3

I/O parameter No. 48 = 2

(Parameter set

tings at shipm

ent)

ON/OFF of output port Nos. 300 and 301

and corr

esponding error lev

el

s

300

301

Message level or lo

w

e

r

{{

Operation-cancellati

on l

e

vel

z{

Cold-st

art level

zz

{

: O

N

z

: OFF

Output port No. 302 bei

ng OFF indicates

an emer

genc

y

stop status.

302

Emergenc

y

stop actuated

z

Emergenc

y

stop not actuated

{

Note)

Parameter setti

ngs at shipm

ent

Want to output signal dur

ing the

AUT

O mode.

Output port No. 303 can be set as an

AUT

O mode output signal.

I/O parameter No. 49 = 1

Output port No. 303

w

ill turn ON during

the AUT

O

mode.

Want to output signal dur

ing

automatic oper

ation.

Output port No. 303 can be set as an

automatic oper

ation output.

I/O parameter No. 49 = 2

Output port No. 303

w

ill turn ON during

automatic oper

ation.

Recogniti

on of

automatic oper

ation:

Recogniti

on of

automatic oper

ation

can be ch

an

ge

d usin

g the setting of

other par

ameter No. 12.

x

Recogniz

e aut

omatic operati

on if a

progr

am is running (either i

n

the

MANU or AUTO mode).

x

Recogniz

e aut

omatic operati

on if a

progr

am is running OR in the

AUT

O mode (regar

dless of

w

h

ether or not

a progr

am is

running).

In either case,

all-oper

ation-

cancellation factor must not be

present.

One of the conditions is recognized

as automatic operation.

x

Other paramet

er No. 12 = 0

Recogniz

e aut

omatic operati

on if a

progr

am is running.

x

Other paramet

er No. 12 = 1

Recogniz

e aut

omatic operati

on if a

progr

am is running OR in the

AUT

O mode.

x

³$OORSHUDWL

RQF

DQFHOODWL

RQIDFW

RULV

QRWSUHVHQW´PHDQVHUU

RUVRI

oper

ation-c

anc

ellati

on l

e

vel

or

higher are

not present AND

emergenc

y-stop signal is not input

AND safet

y

-gat

e signal is not input

AND deadman s

w

itch is ON

(teaching-pendant option).