11

Part 1 Installation

(2) Fuse holder

(general-purpose type only)

This half-cut fuse holder is used to protect overcurrent in the AC input
part. It prevents inflow of abnormal current generated by ground fault, etc.,
and uses a slow-blow fuse specified by IAI.

Overview of Fuse Holder Specifications

n

o

i

t

p

i

r

c

s

e

D

m

e

t

I

Holder

F-22001-A1 by Sato Parts

Fuse type

TWO 250V20A by Fuji Terminal

Melting
characteristics

Slow-blow

* With a compact type, the fuse holder is mounted on the board. Type: FGMT5

AC250V10A by Fuji Terminal

100/200-VAC, single-phase input connector.

AC Power Connector Specifications

w

e

i

v

r

e

v

O

m

e

t

I

Connector name

POWER

Connector

GMSTB2.5/3-STF-7.62 by Phoenix Contact
3-pin, 2-piece connector

Supported cable size

1.25 ~ 2.5 mm

2

(AWG12 ~ 16)

Connected to

AC power source

N

AC power input, N side

L

AC power input, L side

Terminal symbol

PE (Protective grounding line)

(5) External regenerative

unit connector

This connector is used to connect a regenerative resistance unit that may
be required when the controller is used in a high-speed/high-load
environment, etc., and the built-in regenerative resistance capacity is not
sufficient. Whether or not an external regenerative resistance is necessary
will be determined by the specific application such as axis configuration.

External Regenerative Unit Connector Specifications

w

e

i

v

r

e

v

O

m

e

t

I

Connector name

RB

Connector

GIC2.5/3-STF-7.62 by Phoenix Contact
3-pin, 2-piece connector

Cable size

1.0 mm

2

(AWG17 or equivalent), included in the

external regenerative box

Connected to

External regenerative box

Grounding terminal

RB–

Regenerative resistance –

Terminal symbol

RB+

Regenerative resistance +
(Motor-driving DC voltage)

An insufficient regenerative resistance capacity will cause “E65, F63: Regenerative
resistance temperature error.” An insufficient regenerative resistance capacity is
also suspected when “E88: Power system error (Other)” occurs.

*

Type K

(General-purpose Type)

Type J

(Compact Type)

(3) Circuit Protector

This is a surge protector for the overcurrent protection of XSEL-KE AC input.

It prevents inflow of abnormal current generated by ground fault.

(4) AC input connector

Overview of Circuit Protector Specifications