Part 4 Commands

z PAST (Set palletizing reference point)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

PAST

(Position

number)

Prohibited CP

Set the reference point used in palletizing.
If a value is set in operand 1, that position number specified in operand 1 will be used to store the
reference point data.
If no value is set in operand 1, the position-number setting for storing reference point data will become
invalid.
This command is used in conjunction with PASE and PAPT.
If this command is not set, coordinates (0, 0) are used as the reference point. If this command is set, the
set coordinates are used as the reference point in calculating the position coordinates of palletizing
points.
Coordinates in both the PX and PY-axis directions must always be set as the reference-point
coordinates. If a palletizing movement command such as PMVP or PMVL is executed, however,
specification of palletizing Z-axis (PZ-axis) coordinate is optional. If a Z-axis coordinate is specified,
movement in the PZ-axis direction will become enabled. Even if PZ-axis coordinate is not specified,
RSHUDWLRQZLOOVWLOOEHSHUIRUPHG²MXVWWKDWWKHSRVLWLRQZLOOQRWPRYHLQWKH3=D[LVGLUHFWLRQ1RWH
however, that an error will generate in the following cases:
If this command and PZ-axis are set but the PX, PY and PZ-axes are not set as valid axes in the
reference point data, an error will generate when position coordinates are calculated. If the palletizing Z-
axis is not set and the PX and PY-axes are not set as valid axes in the reference point data, an error will
DOVRJHQHUDWHZKHQSRVLWLRQFRRUGLQDWHVDUHFDOFXODWHG³:KHQSRVLWLRQFRRUGLQDWHVDUHFDOFXODWHG´
means when PAPG (get palletizing calculation data) or any palletizing movement command such as
PMVP, PMVL or PACH is executed.
If this command is executed before BGPA is declared (= while palletizing setting is not enabled), an error
will generate.
If the output field is specified, the output w

LOOWXUQ21DIWHUWKLVFRPPDQGLVH[HFXWHG