IAI America XSEL-KE User Manual

Page 126

Advertising
background image

111

Part 4 Commands

[Example 2]

Variable 99 = 00001234h (Decimal: 4660, BCD: 1234)

00001234h

Variable 99 4660 (IN/OUT command)

1234 (INB/OUTB command)

(I/O, flag number upper) (I/O, flag number lower)

FMIO = 0 00h 00h 12h 34h

œ

0000 0000

0000 0000 0001 0010 0011 0100

FMIO = 1 00h 00h 34h 12h

œ

0000 0000

0000 0000 0011 0100 0001 0010

FMIO = 2 12h 34h 00h 00h

œ

0001 0010

0011 0100 0000 0000 0000 0000

FMIO = 3 34h 12h 00h 00h

œ

0011 0100 0001 0010 0000 0000 0000 0000

Temporary data

I/O port, flag status (0 = OFF, 1 = ON)

[Example 3]

Variable 99 = 00000012h (Decimal: 18, BCD: 12)

00000012h

Variable 99 18 (IN/OUT command)

12 (INB/OUTB command)

(I/O, flag number upper) (I/O, flag number lower)

FMIO = 0 00h 00h 00h 12h

œ

0000 0000

0000 0000 0000 0000 0001 0010

FMIO = 1 00h 00h 12h 00h

œ

0000 0000

0000 0000 0001 0010 0000 0000

FMIO = 2 00h 12h 00h 00h

œ

0000 0000

0001 0010 0000 0000 0000 0000

FMIO = 3 12h 00h 00h 00h

œ

0001 0010 0000 0000 0000 0000 0000 0000

Temporary data

I/O port, flag status (0 = OFF, 1 = ON)

OUT(B) command

IN(B) command

OUT(B) command

IN(B) command

OUT(B) command

IN(B) command

OUT(B) command

IN(B) command

OUT(B) command

IN(B) command

OUT(B) command

IN(B) command

Advertising