129
Part 4 Commands
z PDCL (Assign deceleration data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
PDCL
Deceleration
Position
number
CP
[Function] Assign the deceleration data specified in operand 1 to the deceleration item in the position
data specified in operand 2.
The deceleration is set in G and may include up to two decimal places.
[Example 1]
PDCL
0.3
3
Assign 0.3 to the deceleration data at position No. 3.