381

Appendix

INTELLIGENT ACTUATOR

B94

Number of palletizing place

ment points c

alculation error

T

he calculate

d value of nu

mber of palletizing placemen

t points is

abn

ormal.

Check the palletizing count s

etting and nu

mber of even rows in zigzag

setting.

B95

Number of palletizing place

ment points c

oordinates

calculation err

or

A coordinate c

alculation error for palletizin

g placement p

oints occurred. Check the

palletizing refe

rence point, palletizing coun

t setting and p

alletizing pitch

.

C02

Ex

ecutable pr

ogram count over error

Ex

ecution req

uests

w

ere received for programs ex

ceed

ing the number that can be

ex

ecut

ed simu

ltaneously.

C03

Non-registered program specification error

An unregister

ed program number betw

ee

n 1 and 64

w

a

s specified by

a PIO or in

the program.

C04

Program entry point non-detection error

A request

w

as made to ex

ecute a program number for which no program steps

are registered.

C05

Program first-step BG

SR er

ror

The program

specified for e

x

ecut

ion starts

with BG

SR.

C06

Ex

ecutable

st

ep non-detection error

The program

specified for e

x

ecut

ion does

not contain e

x

ecutable program steps.

C07

Subroutine no

n-definition error

The subroutine specified for

call is not defined.

C08

Subroutine du

plicate-definition error

The same subroutine number is defined at multiple locations.

C0A

Tag duplicate-definition error

The same tag number is defined at multiple locations.

C0B

Tag non-definition error

The tag specified as the jum

p destination

of a GOTO statement is not defined.

C0C

DW/IF/IS/

SL p

air-end mismatch error

The branching command syntax

is invalid.

Correspondence

w

ith the la

st

appearing branching comm

and is invalid

w

he

n EDIF,

EDDO or EDSL

is used.

Check the cor

respondence betw

e

en IF/IS

command and EDIF, DO co

mmand and

EDDO or

SLCT command and EDSL.

C0D

DW/IF/IS/

SL n

o pair-end error

EDIF, EDDO

or EDSL

is not

found. Check

the correspondence bet

w

ee

n IF/IS

command and EDIF, DO co

mmand and EDDO or SL

CT command and EDSL.

C0E

BGSR no pair

-end error

There is no EDSR for

BGSR, or no BG

SR for EDSR.

Check the cor

respondence

betw

e

en BG

SR and EDSR.

C0F

DO/IF/IS over-nesting error

The number of nests in a DO or IF/IS command ex

cee

ds the limit value. Check for

ex

ce

ssive nes

ting or branching out of or into the synta

x

u

s

ing a GOTO

command.

C10

SLCT over-ne

sting error

The number of nests in a SL

CT command ex

cee

ds the limit value. Che

ck for

ex

ce

ssive nes

ting or branching out of or into the synta

x

u

s

ing a GOTO

command.

C11

Subroutine ov

er-nesting error

The number of nests in a su

broutine exce

eds the limit v

alue. Check fo

r ex

cess

ive

nesting or branching out of

or into the syntax

using a G

OTO command.

C12

DO/IF/IS unde

r-nesting error

The EDIF or EDDO positio

n is invalid. Che

ck the correspondence bet

ween IF/IS

command and EDIF or DO c

ommand and EDDO, or bra

nching out of

or into the

synta

x

using a

GOTO command.

C13

SLCT under-nesting error

The EDSL p

o

s

ition is inva

lid

. Check the co

rrespondence betw

e

en SL

CT and

EDSR, or branching out of

or into the syntax

using a G

OTO command.