IAI America XSEL-KE User Manual

Page 23

Advertising
background image

8

Part 1 Installation

b. DC solenoid valve, magnet switch, relay

Measure --- Install a diode in parallel with the coil. Determine the diode capacity in accordance with

the load capacity.

In a DC circuit, connecting a diode in reversed polarity will
damage the diode, internal parts of the controller and DC
power supply. Exercise due caution.

The above noise elimination measures are particularly important when a 24-VDC relay is driven
directly by a controller output and there is also a 100-VAC solenoid valve, etc.

Reference Circuit Diagram

Diode

Controller

Surge absorber

Solenoid valve

OUT

COM

CR

+24 V

0 V

100 VAC

CR

0 V

SOL

Advertising