IAI America XSEL-KE User Manual

Page 22

Advertising
background image

7

Part 1 Installation

*

Notes on wiring method
Use twisted cables for the AC power cable and 24-VDC external power cable. Wire the controller
cables separately from lines creating a strong electric field such as power circuit lines (by not bundling
them together or placing in the same cable duct).

If you wish to extend the motor cable or encoder cable beyond the length of each supplied cable,
SOHDVHFRQWDFW,$,¶V7HFKQLFDO6HUYLFH6HFWLRQRU6DOHV(QJLQHHULQJ6HFWLRQ

(2) Noise-elimination grounding

3URYLGHGHGLFDWHGJURXQGLQJIRUWKH)*DQG3(

(3) Noise sources and noise elimination

7KHUHDUHPDQ\QRLVHVRXUFHVEXWVROHQRLGYDOYHV, magnet switches and relays are of particular
concern when building a system. Noise from these parts can be eliminated using the measures
specified below:

D $&VROHQRLGYDOYHPDJQHWVZLWFKUHOD\

Measure --- Install a surge killer in parallel with the coil.

AC power source

Class D grounding

Metal enclosure

&RQQHFWWKH)*WHUPLQDO
with the metal enclosure
using a cable of a
maximum allowable size
RYHUWKHVKRUWHVWGLVWDQFH

N

L

3(

ACIN

;6(/

Controller

Other

equipment

'RQRWFRQQHFWDVDERYH

;6(/

Controller

Other

equipment

6XUJHNLOOHU

m Point

:LUHIURPHDFKFRLORYHUWKHVKRUWHVWGLVWDQFH
Installing a surge killer on the terminal block, etc.,
ZLOOEHOHVVHIIHFWLYHEHFDXVH of a longer distance
from the coil.

Advertising
This manual is related to the following products: