Program format – IAI America XSEL-KE User Manual

Page 299

Advertising
background image

284

Appendix

2. Program

Format

Program Edit Screen (PC Software)

With the X-SEL controllers, you can create a program consisting of up to 6,000 steps.
Edit a program using the PC software or teaching pendant.

No.

: The step number is indicated.

Set a break point. (Breakpoint setting is enabled in the online edit mode.)
8VHWKHPRXVHWRFOLFNWKH³%´FROXPQLQWhe line where you want to set a breakpoint.
2QFHDEUHDNSRLQWLVVHW³%´ZLOOEHVKRZQLQWKHDSSOLFDEOHOLQH 

B :

* Breakpoint --- Set a breakpoint in each step where you want to pause the program

when the program is run by the PC software.

E

: Enter a desired expansion condition (A, O, LD, AB, OB).

1

 6SHFLI\³1´LQGLFDWLQJQHJDWLRQRIWKHLQSXWFRQGLWLRQ

Cnd

: Enter a desired input condition.

Cmnd

: Enter a desired SEL command.

Operand 1

: Enter operand 1.

Operand 2

: Enter operand 2.

Pst

: Enter (operand 3) in the output field.

Comment

: Enter a command (consisting of up to 18 single-byte characters), if necessary.

Advertising
This manual is related to the following products: