12 actuator control command – IAI America XSEL-KE User Manual

Page 170

Advertising
background image

155

Part 4 Commands

1.12 Actuator

Control

Command

z SVXX (Turn ON/OFF servo)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

SVXX

Axis

pattern

Prohibited PE

[Function]

Turn ON/OFF the servos of the axes specified by the axis pattern in operand 1.

SVXX

ON

Turn ON the servo.

OF

Turn OFF the servo.

[Example 1]

SVON

1100

Turn ON the servos of axes 3 and 4. Nothing will occur if the
axis servos are already ON.

[Example 2]

The axis pattern can be specified indirectly using a variable.
When the command in [Example 1] is rephrased based on indirect specification using
a variable:
1100 (binary)

o 12 (decimal)

LET

1

12

Assign 12 to variable 1.

SVON *1