345

Appendix

Axis-Specific Parameters

No Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

76 Home-adjustment

parameter set selection

1 Reference

only

0: Axis-specific parameter No. 21 = Phase-Z

evacuation distance at incremental home
return. Axis-specific parameter No. 12 = Ideal
phase-Z position coordinate. (Units shipped
with application version 0.07 or later)

1: Axis-specific parameter No. 32 is automatically

loaded even when axis-specific parameter No.
33 = 0. When axis-specific parameter No. 33 =
LWLVVHWWR³DFWXDOGLVWDQFH´$[LVVSHFLILF
parameter No. 21 = Offset travel distance at
home return. Axis-specific parameter No. 12 =
Coordinates after offset travel at home return.
Axis-specific parameter No. 26 is invalid.

77 Synchro S pulse

3

0 ~ 99999

Pulse

78 Maximum

takeoff

command amount

0 -3000

~

3000

0.001 mm

Maximum lift command amount before brake unlock
(Input with sign)
(Suppression of momentary drop upon servo ON
when a heavy object is placed)
* Important: Input using the same sign as the rising

coordinate direction. (0.100 mm to 0.500 mm in
absolute value as a guideline)

* The servo-ON check time (axis-specific parameter

No. 30) must also be extended (approx. 1000 to
1500 msec) to provide a sufficient time for rise-
direction torque to follow. (Valid with main
application version 0.25 or later. With version 0.26
or later, this setting is valid only when a brake is
equipped.)

79 Actual takeoff check

distance

5

0 ~ 3000

0.001 mm

Absolute value input (Main application version 0.26
or later)

80 Maximum

forced-feed

range



a

PP )RUUHGXFWLRQRIVHWWOLQJWLPH ,QYDOLGUDQJHLI³´LV

set) (Approx. 1.000 mm as a guideline)
(Available with main application version 0.28 or later)

81 Minimum

forced-feed

range

200

0 ~ 9999

0.001 mm

(Available with main application version 0.28 or later)

82 Medium forced-feed range

600

0 ~ 9999

0.001 mm

(Available with main application version 0.28 or later)

83 Absolute synchro slave-

axis initialization
cancellation

0

0 ~ 5

Valid only with a synchro slave axis. (Main
application version 0.31 or later)

84 Maximum

synchronization

correction speed of
synchro slave axis

5

0 ~ 100

mm/sec

Maximum travel speed for synchronization position
correction of slave axis. Valid only with a synchro
slave axis.
* Note: Not limited by the safety speed. (Main

application version 0.40 or later)

85 Home-return

acceleration/

deceleration

15

1 ~ 300

0.01 G

(Main application version 0.41 or later)

86 Zone 1 MAX

0

-99999999

~ 99999999

0.001 mm

Valid only when MAX > MIN. * Must be inside the
range for at least 3 msec.

87 Zone 1 MIN

0

-99999999

~ 99999999

0.001 mm

Valid only when MAX > MIN. * Must be inside the
range for at least 3 msec.

88 Zone 1 output number

0

0 ~ 899

Physical output port or global flag (Output is invalid if
³´LVLQSXWPXOWLSOHVSHFLILFDWLRQLVLQYDOLG  ³´FDQ
be input in PC software version 1.0.0.0 or later or TP
application version 1.06 or later)

89 Zone 2 MAX

0

-99999999

~ 99999999

0.001 mm

Valid only when MAX > MIN. * Must be inside the
range for at least 3 msec.

90 Zone 2 MIN

0

-99999999

~ 99999999

0.001 mm

Valid only when MAX > MIN. * Must be inside the
range for at least 3 msec.

91 Zone 2 output number

0

0 ~ 899

Physical output port or global flag (Output is invalid if
³´LVLQSXWPXOWLSOHVSHFLILFDWLRQLVLQYDOLG  ³´FDQ
be input in PC software version 1.0.0.0 or later or TP
application version 1.06 or later)

92 Zone 3 MAX

0

-99999999

~ 99999999

0.001 mm

Valid only when MAX > MIN. * Must be inside the
range for at least 3 msec.