IAI America XSEL-KE User Manual

Page 29

Advertising
background image

14

Part 1 Installation

(12) System I/O connector

This connector is used to connect an emergency-stop switch, ENABLE
contact, ready relay, etc.

Connector

MC1.5/6-ST-3.5 by Phoenix Contact; 6-pin, 2-piece
connector

+24V OUT

+24-V power output for emergency
stop

EMG IN

Emergency-stop input

+24V OUT

+24-V power output for safety gate

ENB IN

Safety-gate input

RDY OUT

Terminal assignments

RDY OUT

Ready-status output contact

Current flowing between the emergency-stop contacts:
J type

30 mA

10%

K type

43 mA

10%

Between +24V OUT and EMG IN: Operation is permitted when a contact-
B emergency stop input is received or the line between the two
connectors is shorted. If the line becomes open, an emergency stop will
be actuated and the drive source will be cut off.
Between +24V OUT and ENB IN: Operation is permitted when a contact-
B safety gate input is received or the line between the two connectors is
shorted. If the line becomes open, the drive source will be cut off.
Between RDY OUTs: Contact-A is output under the conditions below.

SYSRDY is output (software = PIO trigger program can be run) and hardware is
normal (emergency stop is not being actuated and hardware error is not being
detected).

The lines between +24V OUT and EMG IN and between +24V OUT and
ENB IN have been shorted by cables before the shipment.

(13) I/O24V power connector

(general-purpose type
only)

This connector is used to externally supply I/O power to the isolated part
when DI and DOs are mounted in the I/O connectors explained in (18)
and (19). 24 V must be supplied externally.

Supported cable size

0.75 ~ 1.25 mm

2

(AWG16)

Connector

MC1.5/2-ST-3.5 by Phoenix Contact; 2-pin, 2-piece
connector
24V IN

+24-V power input for I/Os

Terminal assignments

0V

I/O GND

With a compact type, power is supplied externally to pin Nos. 1 and 50 of
the I/O connector in (18).

(14) Panel window

This window consists of a 4-digit, 7-segment LED display and five LED
lamps that indicate the status of the equipment.

For the information shown on the display, refer to 2, “Explanation of
Codes Displayed on the Panel Window” or the “Error Code Table.”

Meanings of Five LEDs

Name

Status when the LED is lit

RDY

CPU ready (program can be run)

ALM

CPU alarm (system-down level error), CPU hardware error

EMG

Emergency stop has been actuated, CPU hardware error,
power-system hardware error

PSE

Power-system hardware error

CLK

System clock error

Advertising